Back to top

Anti TPO ELISA Kit

Anti TPO ELISA Kit
Anti TPO ELISA Kit

Anti TPO ELISA Kit Specification

  • Shape
  • Rectangular Kit Box
  • Features
  • Ready-to-use, High Sensitivity, High Specificity, Reliable Results
  • Accuracy
  • High Analytical Sensitivity and Specificity
  • Control Type
  • Manual/Software-based Control
  • Temperature Resistance
  • 2C to 8C (Storage)
  • Type
  • ELISA Kit
  • Equipment Type
  • Diagnostic Immunoassay Kit
  • Equipment Materials
  • Plastic Components, Reagent Bottles
  • Material
  • High Quality Biochemical Reagents
  • Application
  • Detection of Anti-Thyroid Peroxidase (Anti-TPO) Antibodies in Human Serum
 

Anti TPO ELISA Kit Trade Information

  • Minimum Order Quantity
  • 1 , , Kit
  • Supply Ability
  • 50000 Kits Per Week
  • Delivery Time
  • 7 Days
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • North America, South America, Asia, Australia, Central America, Eastern Europe, Western Europe, Middle East, Africa
  • Main Domestic Market
  • All India
 

About Anti TPO ELISA Kit

The BI-EIA-THYROID-ANTI-TPO plates are coated with human Thyroid Peroxidase. Serum to be tested is diluted and incubated with the precoated plate. In this step TPO specific antibodies arebound to the immobilized human Thyroid Peroxidase. Non specific antibodies are removed by washing. Anti-human IgG conjugated to horseradish peroxidase (HRP)is added and incubated. In this step the HRP-conjugate is bound to the prebound antigen-anti body complex. Unbound conjugate is removed by washing. The presence of bound enzyme indicating the presence in the specimen of specific antibodies is revealed by a color change in TMB- substrate solution



Efficient and Reliable Anti-TPO Antibody Detection

The Anti TPO ELISA Kit delivers efficient and reliable detection of anti-thyroid peroxidase antibodies, crucial for diagnosing autoimmune thyroid disorders. With high sensitivity and specificity, each test yields precise results in approximately 90 minutes. The kit includes all necessary components, including calibrators and controls, supporting robust and consistent in vitro diagnostics for clinical laboratories.


Comprehensive Components for Simplified Workflow

Each kit is supplied with standard calibrators, high-quality biochemical reagents, TMB substrate, reagent bottles, and plastic components. The inclusion of positive and negative controls enhances confidence in assay accuracy. Compatible with standard microplate readers, the kits ready-to-use format reduces setup time and simplifies operational workflow in laboratory settings.

FAQs of Anti TPO ELISA Kit:


Q: How do I use the Anti TPO ELISA Kit for detecting Anti-TPO antibodies?

A: Follow the comprehensive instruction manual provided in the kit to prepare your samples and reagents. Add 10100 L of human serum to the appropriate wells, perform the assay steps as directed, and use the supplied positive and negative controls for validation. Quantify antibody levels using a standard microplate reader after the colorimetric reaction.

Q: What is the test process and how long does it take to obtain results?

A: The process involves sequential incubation of the sample with reagents, washing, and colorimetric detection using TMB substrate. The total assay duration is approximately 90 minutes from sample addition to result reading, enabling rapid diagnostics in clinical settings.

Q: When should this kit be used and for what purpose?

A: This ELISA kit is intended for in vitro diagnostic use, specifically to detect Anti-TPO antibodies in human serum. It is commonly used when autoimmune thyroid disease is suspected and serves as a reliable tool to aid diagnostic and monitoring decisions.

Q: Where should I store the Anti TPO ELISA Kit and what are the storage requirements?

A: Store the kit at 2C to 8C in a refrigerator and do not freeze. Proper storage ensures optimal reagent stability and maintains the kits analytical performance throughout its 12-month shelf life.

Q: What benefits does this kit offer compared to conventional antibody detection methods?

A: The Anti TPO ELISA Kit provides high sensitivity (>95%) and specificity (>98%) with ready-to-use reagents and robust controls, guaranteeing reliable results. Its efficient workflow and compatibility with standard laboratory equipment make it ideal for clinical diagnostics.

Q: Is equipment required and what are the kits compatibility features?

A: A standard microplate reader is required for the colorimetric detection process. The kits design ensures compatibility with commonly available laboratory equipment and software controls, making it easy to integrate into existing diagnostic setups.

Q: Are calibrators and controls included in the kit and why are they important?

A: Yes, the kit includes standard calibrators and both positive and negative controls. They are essential for validating assay accuracy, ensuring reliable quantification of Anti-TPO antibodies, and enhancing quality control during routine diagnostic testing.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ELISA Kits Category

Varicella-Zoster IgG ELISA Kit

Varicella-Zoster IgG ELISA Kit

Price 20550.00 INR / Kit

Minimum Order Quantity : 50 Kits

Size : Standard

Color : multi color

Shape : Rectangular

Usage : Industrial

Citrulline ELISA Kit

Citrulline ELISA Kit

Price 121500.00 INR / Kit

Minimum Order Quantity : 5 Kits

Size : Standard

Color : multi color

Shape : Rectangular

Usage : Industrial

Digoxin ELISA kit

Digoxin ELISA kit

Price 73500.00 INR / Kit

Minimum Order Quantity : 1 Kit

Size : Standard

Color : multi color

Shape : Rectangular

Usage : Industrial

17-OH Progesterone ELISA kit

17-OH Progesterone ELISA kit

Price 18450 INR / Kit

Minimum Order Quantity : 10 Kits




GST : 09AAGCB6941G1ZJ trusted seller